Electrical specifications for 12V ballasts:
|
Normal operating input voltage range |
9V - 16V |
|
Time limited extended operating input voltage range |
6V - 18V |
|
Starting input voltage range |
8.5V - 18V |
|
Nominal output power |
21/24W 1W |
|
Low output power setting |
18W 1W |
|
Maximum run up output power |
27W |
|
Maximum run up lamp amperes |
1.0 A |
|
Maximum inrush current at 13.5 V |
3 A |
|
Efficiency of D1S and ballast at nominal supply |
85% |
|
Ballast unit efficiency |
86% |
|
Output steady state frequency |
6.7 KHz |
|
Operating temperature range |
-40 to +85 C |
Electrical specifications for 24V ballasts:
|
Normal operating input voltage range |
22V - 29V |
|
Extended operating input voltage range |
16V - 32V |
|
Starting input voltage range |
22V - 32V |
|
Nominal output power |
21/24W 1W |
|
Low output power setting |
18W 1W |
|
Maximum run up output power |
27W |
|
Maximum run up lamp amperes |
1.0 A |
|
Maximum inrush current at 27 V |
1.5 A |
|
Efficiency of D1S and ballast at nominal supply |
85% |
|
Ballast unit efficiency |
87% |
|
Output steady state frequency |
6.7 KHz |
|
Operating temperature range |
-40 to +85 C |
*Xenlight reserves the right to modify / change specifications from time to time without any advance notice.
Other specifications:
Housing: Plastic housing filled with resin.
Connections: Input: 2 wires for power, 1 wire for LIN drive, 1 wire analog remote sense
Output: 3 wires to the bulb. (igniter is necessary)
Weight : Approx 200 g.
|